135
TUNNEL FIXTURES
fax: 586-427-0076
ph:586-427-0070
youtube.com/tsscws
© 2012 TSS, Inc. All Rights Reserved All price & availability subject to change without notice
This comes factory-wired to the
standard time side of the
countdown board which has a
maximum setting of 70 seconds.
If you need more drying time, then
you must disconnect wires
connected to S1 and S2 and connect
them to D1 and D2 (Deluxe time),
which has a maximum setting of 90
seconds.
ON
DELUXE TIME
DEFAULT TIME
40 SECONDS
Maximum time setting
is
90 seconds
.
Maximum time setting
is
70 seconds
.
DEFAULT TIME
20 SECONDS
ADDS 15 SECONDS
ADDS 10 SECONDS
ADDS 15 SECONDS
ADDS 10 SECONDS
ADDS 15 SECONDS
ADDS 10 SECONDS
ADDS 15 SECONDS
ADDS 10 SECONDS
STANDARD TIME
WIRING FOR COUNTDOWN FIXTURE
D
1
D
2
S
1
S
2
Input 120 VAC
Output 12VDC
Transformer
120 VOLT AC input
1 2 3 4
ON
1 2 3 4
OR
STANDARD TIME:
This countdown will be energized
when power is brought to the
transformer on board connected to
S1 and S2.
Standard time has a default time of
20 seconds. A maximum time of 70
seconds can be achieved when all
the dip switches for standard time
are turned on.
See each dip switch’s time
increments above.
DELUXE TIME:
This countdown will be energized
when power is brought to the
transformer on board connected to
D1 and D2.
Deluxe time has a default time of 40
seconds. A maximum time of 90
seconds can be achieved when all
the dip switches for deluxe time are
turned on.
See each dip switch’s time
increments above.
ON
DELUXE TIME
DEFAULT TIME
40 SECONDS
DEFAULT TIME
20 SECONDS
ADDS 15 SECONDS
ADDS 10 SECONDS
ADDS 15 SECONDS
ADDS 10 SECONDS
ADDS 15 SECONDS
ADDS 10 SECONDS
ADDS 15 SECONDS
ADDS 10 SECONDS
STANDARD TIME
WIRING FOR DUAL CYCLE COUNTDOWN FIXTURE
D
1
D
2
S
1
S
2
To turn on Deluxe
Drying countdown
To turn on Standard
Drying countdown
120 VOLT
AC input
120 VOLT
AC input
1 2 3 4
ON
1 2 3 4
Input 120 VAC
Output 12VDC
Transformer
Input 120 VAC
Output 12VDC
Transformer
Maximum time setting
is
90 seconds
.
Maximum time setting
is
70 seconds
.
PLEASE CHECK ONLINE FOR UPDATES ON THE WIRING SCHEMATICS
WIRING FOR COUNTDOWN FIXTURE FOR
PART NUMBERS: T1CS T1CP TCT1S TCT1P
FOLLOW WIRING BELOW TO TURN YOUR EXISTING COUNTDOWN TIMER INTO A DUAL
CYCLE COUNTDOWN
1...,125,126,127,128,129,130,131,132,133,134 136,137,138,139,140,141,142,143,144,145,...192